|
|
|
 |
 |
....Extensometers and Related Products.... |
|
|
|
Click
on the link or photo of the models listed below to see the
individual extensometer data sheets. For models without
active links, please contact Calibration Services for detailed
information.

Axial Extensometers
(Tensile Testing, etc.)
Miniature
Extensometer, Model 3442
Lightweight, for small samples in tensile, compression
and cyclic testing. Gage lengths from 6 to 10 mm and
0.25 to 0.5 inches. Travel ranges from 5 to 100% strain. |
 |
Single
or Dual Range, Long Gage Length, 3543
NEW: Available in 50 mm and 2 inch gage length and larger.
Dual range version with 2 outputs for accurate low travel,
yet captures the full stress-strain curve. Single range
available travel ranges from 25 to 100 mm (1 to 4 inches). |
 |

High
Elongation, Model 3800
For rubber and plastics testing. Gage lengths of 25
or 50 mm and 1or 2 inches. Travel ranges from 125 to
500 mm and 5 to 20 inches |
 |
Laser
Extensometers
Model LE-01 and LE-05
Laser Extensometer
Models LE-01 and LE-05
Non-contacting model, with scanning window of 75 or
125 mm (3 or 5 inches). Resolution to 1 micron. Any
gage length. |
 |
High
Temperature Extensometers
& Furnace Systems
For
Use to 1200 °C, Model 3448
Self supporting model, for use in furnaces and with
induction heating. Gage lengths from 10 to 50 mm and
0.5 to 2 inches. Travel ranges from 5 to 50 percent
strain. |
 |

For
Use to 1200 °C or 1600 °C, Model 3548
Externally supported model, for use in furnaces or
with induction heating. Gage lengths from 10 to 50
mm and 0.5 to 2 inches. Travel ranges from 5 to 50
percent strain. |
 |

To
540 C, Uncooled, Model 3555
For use in chambers where no cooling is possible.
Gage lengths from 10 to 50 mm and 0.5 to 2 inches.
Travel ranges from 5 to 20 percent strain. |
 |
Transverse and Diametral
Extensometers
Transverse
(Diametral), Model 3575
For use on round or flat samples. Adjustable from
0-25 mm or 0-1 inch width Travel ranges from 0.5 to
2.5 mm and 0.02 to 0.1 inches. May be used simultaneously
with axial extensometers like the model 3542. |
 |
Sheet
Metal r-Value, Model 3575AVG
Transverse strain measurement for r-value testing.
Used with 3542. Averages transverse strain measured
at 2 points.
See also the model 3580 listed under high temperature
extensometers above. |
 |
Bi-Axial Extensometers


Fracture Mechanics Gages
Clip-On
Gages, Model 3541
For fracture mechanics testing.
Compressed gage lengths from 3 to 20 mm and 0.2 to
0.5 inches. Travel ranges from 1 to 12 mm and 0.1
to 0.5 inches. |
 |
Rock, Concrete and Asphalt Testing
Axial
Averaging, Model 3542RA
For concrete and rock compression tests. Gage lengths
from 25 to 200 mm and 1 to 8 inches. Travel ranges
from 1.2 to 6 mm and 0.05 to 0.25 inches. Diameters
to 200 mm and 8 inches. |

Deflection Measurement
(Deflectometers)

Calibrators

Electronics
Signal
Conditioner, Model ASC
NEW: Complete analog signal conditioner for strain
gaged sensors. Available in 1 to 4 channel versions.
Includes power supply. |
 |

Excitation Supply,
Model ECX-1
Provides precise DC voltage to power strain gaged
sensors. |
|

Digital Strain Meter,
Model DSM-1
Displays strain readings in engineering units. Includes
analog output. |
|


|
CALIBRATION
SERVICES, INC.
|
300 Buttertown Road
Emlenton, PA 16373
(724) 867-6664 or (800) 793-1870
FAX (724) 867-1346
|
|